Skip to main content

Wildland Urban Interface - Structure Protection

 

The primary consideration of any operation is to assure firefighter and public safety. It is a must to assess potential fire behavior, ingress/egress routes, nature of the threat, hazardous materials, and available water supplies before engaging in the protection of any structure.

Factors that may make an attempt to save a structure too dangerous include:

  • The fire is making a sustained run and there is little or no clearance between the structure and the fuel.
  • The fire behavior is extreme; spot fires are numerous and the spread is outpacing containment.
  • Water supply will not last as long as the threat of the fire.
  • The fire intensity dictates that you leave the fire area immediately.
  • The structure is constructed of wood and has a wood shake roof.
  • The roof of the structure is more than one-quarter involved.
  • There is fire inside of the structure, or windows are broken and there is no way to quickly repair them.
  • You cannot safely remain at the structure because your escape route could become unusable.

When implementing a plan to protect structures, consider the following:

  • Do not enter a burning structure unless you are trained, equipped, and authorized. Firefighter safety and survival is the number one priority.
  • Always stay mobile and wear all personal protective equipment (PPE).
  • Back in equipment to allow for a quick escape.
  • Coil a short, charged line with a fog nozzle on your engine for safety and quick knockdown capability.
  • Don’t make long hose lays.
  • Reserve at least 100 gallons of water in your tank.
  • Check the road system before the fire approaches. Know bridge limits, alternate access routes, and turnarounds for your vehicle and other support vehicles.
  • Determine if residents are home. Leave the inside and outside lights on, regardless of the time of day. Close the garage door.
  • Place the owners’ ladder at a corner of the home on the side with the least fire threat.
  • Coil and charge garden hoses.
  • Check and mark hazardous materials (e.g., Liquefied Propane Gas [LPG] tanks, pesticides, and paint storage.

 

Last Modified / Reviewed:

Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee.


Follow NWCG on Twitter and Facebook

NWCG Latest Announcements

The Incident Position Standards and Next Generation Position Task Book are now available for Status/Check-In Recorder (SCKN)

Date: August 27, 2024
Contact: Incident Planning Subcommittee 

NWCG is excited to announce that the NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32, NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32, and Checking In Resources Customer Service Job Aid, J-111 are now available.

The Performance Support Package, which for SCKN includes the Incident Position Standards, Next Generation Position Task Book, and job aid were developed through the Incident Performance and Training Modernization (IPTM) effort. The Performance Support Package will support trainees, those qualified in the position, and evaluators.

References:

NWCG Status/Check-In Recorder Position Page

NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32

NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32

Checking In Resources Customer Service Job Aid, J-111

The Next Generation Position Task Book and Incident Position Standards are now available for Safety Officer, Field (SOFF)

Date: July 26, 2024
Contact: Risk Management Committee 

NWCG is excited to announce that the NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81 and NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81 are now available.

The Safety Officer, Field (SOFF) is responsible for monitoring operations on an incident from a risk management perspective to provide for the welfare of incident resources and the public. The new Incident Position Standards and Next Generation Position Task Book are developed through the Incident Performance and Training Modernization (IPTM) effort.

References:

NWCG Safety Officer, Field (SOFF) Position

NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81

NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81

Updated NWCG Standards for Electronic Documentation (eDoc), PMS 277

Date: July 25, 2024
Contact: Incident Planning Subcommittee 

The Incident Planning Subcommittee has updated the NWCG Standards for Electronic Documentation (eDoc), PMS 277.

The NWCG Standards for Electronic Documentation (eDoc) establishes the standards for collection and retention of records on wildland fires. This July 2024 update will provide incident management teams the most current standards required to maintain incident records and submit them to host units at the close of an incident.

References:

NWCG Standards for Electronic Documentation (eDoc), PMS 277

eDoc Box Directory (zip file)

NWCG Off-Highway Vehicle Typing Standard Request for Comment

Date: July 24, 2024
Contact: Mobile Fire Equipment Subcommittee 

The Mobile Fire Equipment Subcommittee has released Equipment Bulletin 24-002 NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment. This bulletin outlines the proposed NWCG OHV typing standard, as well as the business need for establishing the standard. Comments on the proposed standard will be accepted through August 15th using the comment form linked below.

References:

ETC-EB-2024-02: NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment

NWCG Off-Highway Vehicle (OHV) Typing Standard Comment Form