Skip to main content

Growing Season Index (GSI)

NFDRS header graphic. Decorative.

 

The Growing Season Index (GSI) In NFDRS 2016, controls live fuel moistures, replacing the 1000-hour and X1000 controls in the 1978/88 versions. The moisture bounds  (30-250 for herbaceous and 50-200 for woody shrubs) and behavior of annuals versus perennials are maintained.

nfdrs-gsi_us.png The Growing Season Index is a simple metric of plant physiological limits to photosynthesis. It is highly correlated to the seasonal changes in both the amount and activity of plant canopies. It predicts the green-up and senescence of live fuels and the influence of water stress events on vegetation. Increasing values of GSI indicate periods of improving conditions for live fuels and decreasing values indicate periods of detrimental weather conditions. GSI is calculated as a function of the three indicators of important weather factors that regulate plant functions. These indicators are combined into a single indicator that integrates the limiting effects of temperature, water and light deficiencies. The importance of each of the three indicators is explained below and a summary of the Growing Season is given at the conclusion.

Minimum Temperature

Many of the biochemical processes of plants are sensitive to low temperatures. Although ambient air temperatures certainly influence growth, constraints on phenology appear to be more closely related to restrictions on water uptake by roots when soil temperatures are sub optimal and many field studies show variable ecosystem responses over a range of minimum temperatures.

Vapor Pressure Deficit (VPD)

Water stress causes partial to complete stomatal closure, reduces leaf development rate, induces the shedding of leaves, and slows or halts cell division. Although models are available to calculate a soil water balance, they require knowledge of rooting depth, soil texture, latent heat losses, and precipitation. As a surrogate, we selected an index of the evaporative demand, the vapor pressure deficit (VPD) of the atmosphere.

Photoperiod or Daylength

Photoperiod provides a plant with a reliable annual climatic cue because it does not vary from year to year at a given location. We assume that photoperiod provides the outer envelope within which other climatic controls may dictate foliar development. Studies have shown that photoperiod is important to both leaf flush and leaf senescence throughout the world.

Upper and lower limits of the indicator functions used to calculate the Growing Season

Input Variable Unconstrained (1) Completely Limiting (0)
Minimum Temperature 5ºC /41º F -2ºC /28º F
Vapor Pressure Deficit (Pascals) 900 Pascals 4100 Pascals
Photoperiod (Daylength) 11 hours 10 hours

Learn more about the Growing Season Index (GSI)

 

NWCG Latest Announcements

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1