Dozers

Dozer Typing Standard

Requirements Type 1 Type 2 Type 3 Type 4
Net HP Range* 240 and up 150 - 250 99 - 165 50 - 110
Minimum Base Weight** 60,000 lbs. 35,000 lbs. 20,000 lbs. 10,000 lbs.
*Manufacturer’s published rated net horsepower (HP). Horsepower rating taken at the flywheel with all the engine accessories installed not counting transmission losses or anything after the flywheel.
**Manufacturer’s published base weight for dozer including equipped track width and blade configuration, equipment fluids, etc. If a published base weight is unavailable, a certified in-service weight shall be used.
Base operational weight is only used for typing. Final in-service dozer weight will be higher and include additional accessories such as winch, grapple, forestry package, etc. Final in-service dozer weight must be used when calculating hauler capacity, bridge weight limits, etc.

 


Engines

The NWCG categorizes information on fire apparatus into logical groups and provides common options often requested by fire managers. The Incident Command System (ICS) uses this system based on the equipment capability. The table below shows NWCG minimum performance requirements for structure and, wildland engine resource types. Additional information for required crew training and equipment recommendations can be found at the position catalog.

Engine Typing Standard

Types 1 and 2 are structure; Types 3-7 are wildland

Requirements Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7
Tank minimum capacity (gal) 300 300 500 750 400 150 50
Pump minimum flow (gal/min) 1,000 500 150 50 50 50 10
At rated pressure (psi) 150 150 250 100 100 100 100
Hose: 2½-inch 1,200 1,000 N/A N/A N/A N/A N/A
Hose: 1½-inch 500 500 1,000 300 300 300 N/A
Hose: 1-inch N/A N/A 500 300 300 300 200
Ladders per NFPA 1901 Yes Yes N/A N/A N/A N/A N/A
Master stream 500 gal/min. Yes N/A N/A N/A N/A N/A N/A
Pump and roll N/A N/A Yes Yes Yes Yes Yes
Maximum GVWR (lb) N/A N/A N/A N/A 26,000 19,500 14,000
Personnel (minimum) 4 3 3 2 2 2 2

N/A = Not applicable
NFPA = National Fire Protection Association
GVWR = Gross Vehicle Weight Rating

Notes:

  1. All types shall meet federal, state and agency requirements for motor vehicle safety standards, including all gross vehicle weight ratings when fully loaded.
  2. Type 3 engines and tactical water tenders shall be equipped with a foam proportioner system.
  3. All water tenders and engine types 3 through 6 shall be able to prime and pump water from a 10 foot lift.
  4. Personnel shall meet the qualification requirements of NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

Engine Resources


Tractor Plows / Dozer Plows

Tractor Plow / Dozer Plow Standard

Requirements Type 1 Type 2 Type 3 Type 4
Net HP Range* 240 and up 150 - 250 99 - 165 50 - 110
Minimum Base Weight** 60,000 lbs. 35,000 lbs. 20,000 lbs. 10,000 lbs.
*Manufacturer’s published rated net horsepower (HP). Horsepower rating taken at the flywheel with all the engine accessories installed not counting transmission losses or anything after the flywheel.
**Manufacturer’s published base weight for dozer including equipped track width and blade configuration, equipment fluids, etc. Includes published blade weight whether or not the tractor plow / dozer plow is equipped with a front blade. Does not include weight of plow. If a published base weight is unavailable, a certified in-service weight shall be used.
Base operational weight is only used for typing. Final in-service weight will be higher and include additional accessories such as plow, winch, grapple, forestry package, etc. Final in-service weight must be used when calculating hauler capacity, bridge weight limits, etc.

 


Water Tenders

The NWCG categorizes information on fire apparatus into logical groups and provides common options often requested by fire managers. The Incident Command System (ICS) uses this system based on the equipment capability. The table below shows NWCG minimum performance requirements for water tenders. Additional information for required crew training and equipment recommendations can be found at the position catalog.

Water Tender Typing Standard

Requirements Support Type 1 Support Type 2 Support Type 3 Tactical Type 1 Tactical Type 2
Tank capacity (gal) 4,000 2,500 1,000 2,000 1,000
Pump minimum flow (gal/min) 300 200 200 250 250
At rated pressure (psi) 50 50 50 150 150
Maximum refill time (minutes) 30 20 15 N/A N/A
Pump and roll N/A N/A N/A Yes Yes
Personnel (minimum) 1 1 1 2 2
N/A = Not applicable

Water Tender Resources

 

The National Wildfire Coordinating Group (NWCG) provides national leadership to enable interoperable wildland fire operations among federal, state, tribal, territorial, and local partners. NWCG operations standards are interagency by design; they are developed with the intent of universal adoption by the member agencies. However, the decision to adopt and utilize them is made independently by the individual member agencies and communicated through their respective directives systems.

NWCG Latest Announcements

The Incident Position Standards and Next Generation Position Task Book are now available for Status/Check-In Recorder (SCKN)

Date: August 27, 2024
Contact: Incident Planning Subcommittee 

NWCG is excited to announce that the NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32, NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32, and Checking In Resources Customer Service Job Aid, J-111 are now available.

The Performance Support Package, which for SCKN includes the Incident Position Standards, Next Generation Position Task Book, and job aid were developed through the Incident Performance and Training Modernization (IPTM) effort. The Performance Support Package will support trainees, those qualified in the position, and evaluators.

References:

NWCG Status/Check-In Recorder Position Page

NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32

NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32

Checking In Resources Customer Service Job Aid, J-111

The Next Generation Position Task Book and Incident Position Standards are now available for Safety Officer, Field (SOFF)

Date: July 26, 2024
Contact: Risk Management Committee 

NWCG is excited to announce that the NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81 and NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81 are now available.

The Safety Officer, Field (SOFF) is responsible for monitoring operations on an incident from a risk management perspective to provide for the welfare of incident resources and the public. The new Incident Position Standards and Next Generation Position Task Book are developed through the Incident Performance and Training Modernization (IPTM) effort.

References:

NWCG Safety Officer, Field (SOFF) Position

NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81

NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81

Updated NWCG Standards for Electronic Documentation (eDoc), PMS 277

Date: July 25, 2024
Contact: Incident Planning Subcommittee 

The Incident Planning Subcommittee has updated the NWCG Standards for Electronic Documentation (eDoc), PMS 277.

The NWCG Standards for Electronic Documentation (eDoc) establishes the standards for collection and retention of records on wildland fires. This July 2024 update will provide incident management teams the most current standards required to maintain incident records and submit them to host units at the close of an incident.

References:

NWCG Standards for Electronic Documentation (eDoc), PMS 277

eDoc Box Directory (zip file)

NWCG Off-Highway Vehicle Typing Standard Request for Comment

Date: July 24, 2024
Contact: Mobile Fire Equipment Subcommittee 

The Mobile Fire Equipment Subcommittee has released Equipment Bulletin 24-002 NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment. This bulletin outlines the proposed NWCG OHV typing standard, as well as the business need for establishing the standard. Comments on the proposed standard will be accepted through August 15th using the comment form linked below.

References:

ETC-EB-2024-02: NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment

NWCG Off-Highway Vehicle (OHV) Typing Standard Comment Form