Skip to main content

Fuel Moisture: Dead Fuel Moisture Content

  1. Nelson Model 1 and 10-hr Fuel Moisture Estimation Methods
  2. Fosberg Model 1-hr Fuel Moisture Estimation Methods
  3. 10-hr, 100-hr and 1000-hr Fuel Moisture Content
  4. Fuel Moisture Conditioning in U.S. Spatial Fire Growth Models

Nelson Model 1 and 10-hr Fuel Moisture Estimation Methods

Ralph M. Nelson (2000) developed a fuel moisture model for estimating the diurnal fuel moisture changes in a 10-hr NFDRS fuelstick. Requiring hourly observations, it produces a more dynamic estimate that better reflects changes in precipitation, humidity and sunshine. 2016 NFDRS uses this methodology.

SimpleFFMC 1-hr Fuel Moisture Estimation Tables based on the Nelson Model, has been calibrated for the southeastern U.S. by W. Matt Jolly (2016) and is available as a web-app for online users.

Return to Top

Fosberg Model 1-hr Fuel Moisture Estimation Methods

Michael A. Fosberg and John E. Deeming (1971) documented procedures for estimating 1 and 10-hour Timelag Fuel Moistures. The methodology, along with seasonal adjustment tables, were integrated into Richard Rothermel’s (1983) tools and methods for surface fire behavior predictions. 78/88 NFDRS use this.

Daytime Estimation Procedure

  1. Using Table A, determine Reference Fuel Moisture (RFM). Percentage from intersection of temperature and relative humidity. Record this RFM percentage.
  2. Select Table B, C, or D to adjust RFM for local conditions by finding current month in table title.
  3. Is the fine fuel more than 50% shaded by canopies and clouds? If yes, use bottom shade) portion of table. If no, use top exposed portion of table.
  4. Determine the appropriate row based on aspect and slope.
  5. Determine the appropriate column based on time of day and elevation of area of concern when compared to the wx site elevation. Use (A)bove if the fire is 1-2000’ above your location, (B)elow if the fire is 1-2000’ below you, and (L)evel if the fire is within 1000’ above or below you.
    Image
    Below fire, at fire level, and above fire chart.
  6. Obtain the 1-hr Moisture Content Correction (%) from the intersection of row and column.
  7. Add the resulting 1-hr Moisture Content Correction (%) to the Reference Fuel Moisture (%).

Nighttime Estimates of 1-hr Fuel Moisture

Published Reference Fuel Moisture and Correction Tables for Nighttime Conditions are not included here based on recommendation from Pat Andrews at the Missoula Fire Lab. She recommends:

  • Estimate Dry Bulb Temperature and RH for the location of interest.
  • Use Table A to estimate the Reference Fuel Moisture.
  • Use the appropriate 1-hr Moisture Content Correction Table based on the time of the year.
  • Obtain the correction for 0800, shaded conditions, and appropriate aspect from that table and add it to the Reference Fuel Moisture to estimate 1-hr moisture content for nighttime conditions.

Table A. Reference Fuel Moisture

Image
1-hr Fuel Reference Fuel Moisture Table. Integrates Dry Bulb Temperature and Relative Humidity.

Table B. 1-hr Fuel Moisture Corrections-May-June-July

Image
1-hr Fuel Moisture Corrections for May, June, and July. Used to adjust reference fuel moisture to local conditions of shading, slope, aspect, and time of day.

Table C. 1-hr Fuel Moisture Corrections-Feb-Mar-Apr and Aug-Sep-Oct

Image
1-hr Fuel Moisture Corrections for February, March, April, August, September, and October. Used to adjust reference fuel moisture to local conditions of shading, slope, aspect, and time of day.

Table D. 1-hr Fuel Moisture Corrections-Nov-Dec-Jan

Image
1-hr Fuel Moisture Corrections for November, December, and January. Used to adjust reference fuel moisture to local conditions of shading, slope, aspect, and time of day.

Return to Top

10-hr, 100-hr and 1000-hr Fuel Moisture Content

10-hr and 100-hr Fuel Moisture may be estimated in the following ways and applied along with the Fosberg fuel moistures in surface fire behavior predictions. 1000-hr fuel moisture is not usually needed for fire behavior calculations.

  • After estimating 1-hr moisture content, 10-hr and 100-hr fuel moisture content can be estimated by adding incremental amounts (e.g. adding 1-2% for 10-hr and 2-4% for 100-hr).
  • Using a local RAWS station or the Geographic Area’s Predictive Service summaries, 78/88 NFDRS moisture content estimates or forecast values that utilize the Fosberg Model may be available for each of these fuel categories.
  • The National Fuel Moisture Database may have sampling locations near your setting that have estimates for these fuel moistures.

In NFDRS, if danger rating calculations are suspended in the dormant season, default dormant fuel moistures are provided for 100-hr (10%-25%) and 1000-hr (15%-30%) fuel moistures when calculations are restarted in the spring. Default values are established with climate class designation for the location.

Return to Top

Fuel Moisture Conditioning in US Spatial Fire Growth Models

Deterministic spatial analyses in WFDSS (Basic, STFB, and NTFB) use estimates from historic weather data in the WIMS implementation of NFDRS as default initial fuel moistures inputs. Forecast and/or observed weather (for retrospective periods) from the selected weather stations are used to estimate hourly adjustments to dead fuel moistures for those analyses.  At this writing in 2019, initial dead fuel moistures in deterministic analyses default to estimates using the Fosberg dead fuel moisture model while conditioning weather uses the Nelson model to adjust 1-hr, 10-hr and 100-hr fuel moisture content over 1 to several days.. In most cases, one or two days of conditioning is sufficient. 

Take care to review the conditioning weather inputs for both observed and forecast days.  Precipitation amounts, high overnight humidity recovery, and/or significant cloud cover can raise fine fuel moisture significantly.  Use the Basic Outputs from Flammap or Short Term Fire Behavior analyses to review resulting 1-hr and 1-hr fuel moistures and edit inputs as necessary.

Desktop software (FLAMMAP and FARSITE) can use any initial fuel moisture and weather stream that the user supplies to apply these conditioning adjustments.

WFDSS FSPro draws its dead fuel moistures (1-hr, 10-hr, and 100-hr) in the ERC table from the WIMS implementation of NFDRS.  It ranks and groups ERC(g) values from the selected weather station climatology and provides average fuel moisture values from the underlying data for each of those groups, or percentile classes. As of this writing in 2019, it uses 78 Fuel Model G and the Fosberg model for all dead fuel moisture defaults. They are held static during the simulation and are not conditioned or changed during any simulation for the period that they are drawn from and used.

Return to Top

NWCG Latest Announcements

The Incident Position Standards and Next Generation Position Task Book are now available for Status/Check-In Recorder (SCKN)

Date: August 27, 2024
Contact: Incident Planning Subcommittee 

NWCG is excited to announce that the NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32, NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32, and Checking In Resources Customer Service Job Aid, J-111 are now available.

The Performance Support Package, which for SCKN includes the Incident Position Standards, Next Generation Position Task Book, and job aid were developed through the Incident Performance and Training Modernization (IPTM) effort. The Performance Support Package will support trainees, those qualified in the position, and evaluators.

References:

NWCG Status/Check-In Recorder Position Page

NWCG Incident Position Standards for Status/Check-In Recorder, PMS 350-32

NWCG Position Task Book for Status/Check-In Recorder (SCKN), PMS 311-32

Checking In Resources Customer Service Job Aid, J-111

The Next Generation Position Task Book and Incident Position Standards are now available for Safety Officer, Field (SOFF)

Date: July 26, 2024
Contact: Risk Management Committee 

NWCG is excited to announce that the NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81 and NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81 are now available.

The Safety Officer, Field (SOFF) is responsible for monitoring operations on an incident from a risk management perspective to provide for the welfare of incident resources and the public. The new Incident Position Standards and Next Generation Position Task Book are developed through the Incident Performance and Training Modernization (IPTM) effort.

References:

NWCG Safety Officer, Field (SOFF) Position

NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81

NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81

Updated NWCG Standards for Electronic Documentation (eDoc), PMS 277

Date: July 25, 2024
Contact: Incident Planning Subcommittee 

The Incident Planning Subcommittee has updated the NWCG Standards for Electronic Documentation (eDoc), PMS 277.

The NWCG Standards for Electronic Documentation (eDoc) establishes the standards for collection and retention of records on wildland fires. This July 2024 update will provide incident management teams the most current standards required to maintain incident records and submit them to host units at the close of an incident.

References:

NWCG Standards for Electronic Documentation (eDoc), PMS 277

eDoc Box Directory (zip file)

NWCG Off-Highway Vehicle Typing Standard Request for Comment

Date: July 24, 2024
Contact: Mobile Fire Equipment Subcommittee 

The Mobile Fire Equipment Subcommittee has released Equipment Bulletin 24-002 NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment. This bulletin outlines the proposed NWCG OHV typing standard, as well as the business need for establishing the standard. Comments on the proposed standard will be accepted through August 15th using the comment form linked below.

References:

ETC-EB-2024-02: NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment

NWCG Off-Highway Vehicle (OHV) Typing Standard Comment Form